MICRO H - Calibration of the hand operated wheel balancing machine
Machine should be put on four rubber pads.
Connect the machine to a source of power (one-phase AC or 12V DC).
Switch on a power supply.
Fix the calibration instrument.
Press and hold down the button CAL without introducing the rim parameters.
Accelerate handly the spindle to a speed higher than 120 RPM.
After reaching a speed of 120 RPM the calibration process will begin. The results will be displayed.
The other way to make the calibration is to use a wheel and balancing weight 80g.
After proper fixing a wheel introduce its parameters (width, diameter and distance).
After introducing wheel’s parameters, press and hold down button CAL and then press button “+” and it hold down on some seconds.
Fix the balancing weight 80g on the outside plane of the rim and accelerate the spindle to a speed higher than 115 RPM.
- After reaching a speed of 115 RPM the calibration process will begin. The results will be displayed when the calibration process will end.
Fix the wheel by inside cone.